Ashly TM-360 Specifications Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
5
Operating Manual - TM-360 Public Address Amplier
Rear Panel Features
1) AC Mains
This is the AC cord for connecting to 120VAC mains, 60Hz, 24W.
2) Main Speaker Outputs
This 5.08mm Euroblock connector is used for the main speaker output wiring. For low imped-
ance speaker loads, minimum 4
,
connect between the COM and 16V/4
pins. For 25V or 70V
speaker loads (70V and 100V output taps on 230VAC models), the LINK wire must rst be installed
between the 16V/4
pin and OPT IN pin, then connect the speaker load between COM and 25V or
70V pins.
3) Zone 2 and Preamp Outputs
In addition to the main 60 Watt amplier output, there is a separate ZONE 2 output which is a
switch selectable mix of channels 1, 2, or 3. This output is not effected by the priority ducking/mute
action or by the bass/treble EQ controls.
The ZONE-2 output provides two signals; 1) a low impedance output that is capable of contin-
uously driving 1 Watt into an 8 Ohm loudspeaker, and 2) a 600 Ohms transformer balanced output.
Zone 2 output is controlled by the rear panel Zone 2 level control, as well as the three channel assign
DIP switches.
The PRE OUT connection is used for driving additional external devices with the same signal
that drives the main TM-360 power amplier. The PRE OUT 600
W
output signal is taken before the
master volume control.
4) Zone 2 Level Control
This controls the level of the Zone 2 output signal.
Page view 4
1 2 3 4 5 6 7 8 9 10 ... 15 16

Comments to this Manuals

No comments