NX3.04
NX3.02
NX1.54
NX1.52
NX8004
NX8002
NX4004
NX4002
NX SERIES
800 & 400 Wa Models3000 & 1500 Wa Models
nX Series
nX
3.04
nX
3.02
nX
1.54
nX
1.52
nX
8004
nX
8002
nX
4004
nX
4002
Channels 4 2 4 2 4 2 4 2
*Max Output Power: Measured in Was, Per Channel, Low-Z Output, All Channels Driven
2 Ohms 3,000 3,000 1,500 1,500 800 800 400 400
4 Ohms 2,000 2,000 1,500 1,500 800 800 400 400
8 Ohms 1,250 1,250 1,250 1,250 800 800 400 400
*Low Z Output: Measured in Was, Bridge Mode, All Channels Driven
4 Ohms 6,000 6,000 3,000 3,000 1600 1600 800 800
8 Ohms 4,000 4,000 3,000 3,000 1600 1600 800 800
*70V, 100V Output: Measured in Was, All Channels Driven
70V (per channel) 2,450 2,450 1,500 1,500 800 800 400 400
100V (per channel) 1,250 1,250 1,250 1,250 800 800 400 400
Total Power Draw: Measured in Was, Total for all Channels
Sleep Mode < 1 < 1 < 1 < 1 < 1 < 1 < 1 < 1
Standby Mode 70 40 70 40 40 25 40 25
Idle (no signal) 100 55 100 55 70 40 70 40
Current Draw: Measured in Amps, Total for all Channels, 120VAC, Divide by 2 for 240V
Sleep Mode 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Standby Mode 1.30 0.70 1.30 0.70 0.70 0.38 0.70 0.38
Idle (no signal) 1.85 1.00 1.85 1.00 1.30 0.70 1.30 0.70
Max Current Draw: Measured in Amps, Typical Input, All Channels Driven, Divide by 2 for 240V
⅛ Max Power @ 2 Ohms 29.5 14.7 16.0 8.0 8.8 4.6 5.0 2.6
Thermal Dissipaon: BTU/hr, Typical Input, Total for all Channels
Sleep mode < 3.4 < 3.4 < 3.4 < 3.4 < 3.4 < 3.4 < 3.4 < 3.4
Standby mode 238 136 238 136 136 85 136 85
Idle (no signal) 340 187 340 187 238 136 238 136
⅛ Max Power @ 2 Ohms 2,720 1,360 1,700 850 970 495 595 305
70V Rated
100V Rated
High-Z/Low-Z
Selectable
5-Year Warranty
Ashly EMS™
Hand-built in
Webster, NY
Ashlys new line of nX Power Ampliers
feature lightweight, energy-ecient
Class-D switching amplier technology
combined with a switch mode power
supply. nX ampliers are available in three
product families (nX, nXe, nXp) and are
designed to meet the most demanding
live sound and xed installaon sound
systems in stadiums, arenas, performance
venues, worship spaces and convenon
centers.
nX Series is the base level amplier in
the line, available in either 2 or 4-channel
models. Use rear panel DIP switches to
program each channel output for either
High-Z (70V or 100V Constant Voltage)
or Low-Z (stable down to 2 Ohms)
operaon. When in sleep mode, the
nX ampliers draw less than 1 Wa.
nX Series Features:
2 and 4-channel high-output, lightweight
ampliers with programmable output on
each channel (High-Z or Low-Z, selected
via rear panel DIP switches)
Power-saving, Energy Management
System
(Ashly EMS™) automac
<1W sleep-mode (defeatable)
Front panel power switch and level
controls (can be disabled for security)
Rear panel DIP switches per channel for
selecon of high pass lter, limiter, input
gain, and High-Z or Low-Z speaker output
conguraon
Remote DC level control on each input
channel
Switch mode power supply automacally
detects 120V or 240V AC operaon
Extensive protecon circuitry, connu-
ously variable cooling fans
Mulple independent internal power
supplies provide increased channel
separaon and reliability
Neutrik® Combo XLR – 1/4” TRS jack plus
Euroblock input connectors
Neutrik® speakON® twist locking loud-
speaker connectors for security, safety,
and reliability
Neutrik® powerCON® detachable AC
mains connector
Power AmPlifiers w/ ProgrAmmAble outPuts
* Measurements based on CEA-2006/490A, 20mS 1kHz 1% THD+N, 480mS 1kHz -20dB.
<1W sleep mode can be defeated for applications that are subject to third-party performance standards that prohibit a sleep
mode, including those used for Mass Notification and Emergency Communication Systems and those subject to ANSI/UL 2572.
Note: When making a true comparison of energy efficiency, one must look at the Thermal Dissipation (BTU/hr) numbers for a
product. All other efficiency, i.e. "percentage" numbers are not standards based, and therefore may be marketing hype. Ashly
Audio builds highly efficient Class-D amplification with SMPS that will equal or surpass the competition on BTU/hr thermal output
(unused energy given off as heat). Please check our published BTU/hr specifications for more information.
Page view 0
1 2 3 4

Summary of Contents

Page 1 - NX SERIES

Ashly Audio, Inc. | 847 Holt Road | Webster, NY 14580-9103 USA | US toll free: +1-800-828-6308 | tel: +1-585-872-0010 | fax: +1-585-872-0739 | sales@a

Page 2

Ashly Audio, Inc. | 847 Holt Road | Webster, NY 14580-9103 USA | US toll free: +1-800-828-6308 | tel: +1-585-872-0010 | fax: +1-585-872-0739 | sales@a

Page 3

Ashly Audio, Inc. | 847 Holt Road | Webster, NY 14580-9103 USA | US toll free: +1-800-828-6308 | tel: +1-585-872-0010 | fax: +1-585-872-0739 | sales@a

Page 4

Ashly Audio, Inc. | 847 Holt Road | Webster, NY 14580-9103 USA | US toll free: +1-800-828-6308 | tel: +1-585-872-0010 | fax: +1-585-872-0739 | sales@a

Comments to this Manuals

No comments